DE-7200 Centrifuge
Variable Frequency Drive
Issued 30 Oct 09 Rev 01 Jan 14
Maintenance & Operation Manual
DISCLAIMER
Derrick Corporation has taken care to ensure that all of its maintenance and operation manuals are accurate. However, we offer no
guarantees or warranties in this regard. Our manuals are provided only as a guide to assist with the maintenance and operation.
Derrick Corporation takes no responsibility for any losses, damage, or injuries that may occur as a result of using any of our manuals.
It is ultimately the operator’s responsibility to ensure that the operation, repair, and maintenance of equipment complies with all
applicable national and local regulations, including safety regulations.
THIS MANUAL IS PROVIDED BY DERR
ICK CORPORATION ON AN “AS IS” BASIS AND DERRICK CORPORATION EXPRESSLY
DISCLAIMS ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL DERRICK CORPORATION BE LIABLE
FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER WITH
RESPECT TO THE MANUAL AND EQUIPMENT.
Derrick Equipment Company
15630 Export Plaza Drive
Houston, Texas 77032
Phone: 281.590.3003
Toll Free: 1.866.DERRICK
Fax: 281.442.6948
www.derrickequipment.com
Vista de pagina 0
1 2 3 4 5 6 ... 166 167

Indice de contenidos

Pagina 1 - DE-7200 Centrifuge

DE-7200 Centrifuge Variable Frequency Drive Issued 30 Oct 09 Rev 01 Jan 14 Maintenance & Operation Manual DISCLAIMER Derrick C

Pagina 2

INTRODUCTION 1-2 20 Sep 12 DE-7200VFDCentrifuge EQUIPMENT USE The DE-7200 VFD centrifuge is designed for removing low and high specific gravity soli

Pagina 3

MAINTENANCE 5-38 31 Dec 13 DE-7200VFDCentrifuge Figure 5-15. PLC Indicators

Pagina 4

MAINTENANCE 31 Dec 13 5-39 DE-7200VFDCentrifuge CONTROL COMPONENT INDICATORS (CONT’D) Figure 5-16. Transmitter/Intrinsic Barrier Indicators Figur

Pagina 6 - Section

SECTION 8 - REFERENCE DRAWINGS 01 Sep 11 1-1 DE-7200VFDCentrifuge This section contains Derrick engineering drawings for your equipment. These

Pagina 13 - Vibration Switch

INTRODUCTION 20 Sep 12 1-3 DE-7200VFDCentrifuge Rotating Assembly The rotating assembly consists of a cylindrically shaped, bowl, conveyor assembly

Pagina 24 - EQUIPMENT HANDLING

INTRODUCTION 1-4 20 Sep 12 DE-7200VFDCentrifuge pre-set torque limit is reached, the control system automatically reduces the feed rate to enable th

Pagina 35

INTRODUCTION 20 Sep 12 1-5 DE-7200VFDCentrifuge the upper setpoint, the compressor and condenser motors are cycled on to provide cooling. Upon reac

Pagina 46

INTRODUCTION 1-6 20 Sep 12 DE-7200VFDCentrifuge The case is bolted onto the welded steel base assembly, which contains mounting provisions for the b

Pagina 48 - Pond Depth (Cont’d)

ITEM QTY PART NUMBER DESCRIPTION01 X 16472-01-002 ASSEMBLY COMPLETE02 1 16396-01-008 ENCLOSURE ASSEMBLY03 1 16400-01-003 DOOR ASSEMBLY04 1 16401-01-00

Pagina 50 - MOTOR TORQUE TREND

ITEMQTY DRAWING NUMBER DESCRIPTION01 X 16472-01-003 ASSEMBLY COMPLETE02 1 16396-01-003 ENCLOSURE ASSEMBLY03 1 16400-01-003DOOR ASSEMBLY04 1 16401-01-0

Pagina 52 - ALARM AND FAULT MESSAGES

ITEMQTYPART NUMBERDESCRIPTION01 X 16472-01-004 ASSEMBLY COMPLETE02 1 16396-01-003ENCLOSURE ASSEMBLY03 1 16400-01-003 DOOR ASSEMBLY04 1 16401-01-002COV

Pagina 54 - PUMP VFD FAULT STATUS

Parts ListITEMQTY DRAWING NUMBER DESCRIPTION 01 X 16472-01-005 ASSEMBLY COMPLETE02 1 16396-01-003 ENCLOSURE ASSEMBLY03 1 16400-01-003DOOR ASSEMBLY

Pagina 56 - SETUP SCREEN

SECTION 9 - INSTALLATION AND MAINTENANCE LOG 30 Oct 09 9-1 DE-7200VFDCentrifuge PURPOSE This section should be used by operating and maintenanc

Pagina 57 - CLEAN OUT

INTRODUCTION 20 Sep 12 1-7 DE-7200VFDCentrifuge Figure 1-4 Centrifuge Operation CONTROL SYSTEM Centrifuge operation is supervised by a programmab

Pagina 58 - Manual Cleanout

INSTALLATION & MAINTENANCE LOG 9-2 30 Oct 09 DE-7200VFDCentrifuge

Pagina 59 - Main Bearing Temperatures

INSTALLATION AND MAINTENANCE LOG 30 Oct 09 9-3 DE-7200VFDCentrifuge

Pagina 60 - Conveyor Clutch Trip

INSTALLATION & MAINTENANCE LOG 9-4 30 Oct 09 DE-7200VFDCentrifuge

Pagina 61 - Mechanical Shutdown

INSTALLATION AND MAINTENANCE LOG 30 Oct 09 9-5 DE-7200VFDCentrifuge

Pagina 62

INSTALLATION & MAINTENANCE LOG 9-6 30 Oct 09 DE-7200VFDCentrifuge

Pagina 63 - SECTION 5 - MAINTENANCE

APPENDIX A - HMI SERVER SYSTEM 15 May 13 A-1 Appendix A-HMIServerSystem DESCRIPTION This Appendix contains instructions for installing, connect

Pagina 64 - PREVENTIVE MAINTENANCE

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM A-2 15 May 13 Appendix A-HMIServerSystem INSTALLATION All safety procedures included in the Operation

Pagina 65 - GEARBOX OIL LEVEL CHECK

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM 15 May 13 A-3 Appendix A-HMIServerSystem Figure A-3. Electrical Connections to Router Switchgear Box

Pagina 66 - GEARBOX OIL CHANGE

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM A-4 15 May 13 Appendix A-HMIServerSystem Control Cabinet Connections to Router Switchgear Box The foll

Pagina 67 - DRIVE BELT REPLACEMENT

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM 15 May 13 A-5 Appendix A-HMIServerSystem 5. Connect a CAT5 cable to Ethernet switch in Switchgear

Pagina 68

INTRODUCTION 1-8 20 Sep 12 DE-7200VFDCentrifuge PRODUCT SUPPORT Derrick Corporation offers 24-hour per day, 7-day per week product support. Product

Pagina 69 - Bypassing Purge System

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM A-6 15 May 13 Appendix A-HMIServerSystem Operation (Cont’d) IP Address If connecting to LAN 1, the sta

Pagina 70 - Initial Purge Time Setting

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM 15 May 13 A-7 Appendix A-HMIServerSystem Figure A-7. HMI Server Home Screen Figure A-8. Operation S

Pagina 71 - Leakage Compensation Test

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM A-8 15 May 13 Appendix A-HMIServerSystem Figure A-10. Pump Setup Screen Figure A-11. Support-Activat

Pagina 72

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM 15 May 13 A-9 Appendix A-HMIServerSystem Figure A-14. DeskLock Screen Troubleshooting Network Connec

Pagina 73 - Rotating Assembly Removal

APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM A-10 15 May 13 Appendix A-HMIServerSystem Figure A-15. Customer PC Test Connections to Ping Routers R

Pagina 77 - RECOMMENDED SPARE PARTS

SECTION 2 - SAFETY 30 Sep 13 2-1 DE-7200VFDCentrifuge GENERAL This section contains a summary of WARNINGS used in this manual and a list of mater

Pagina 78

SAFETY 2-2 30 Sep 13 DE-7200VFDCentrifuge WARNING! ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL CODES.

Pagina 79 - Troubleshooting Procedure

SAFETY 30 Sep 13 2-3 DE-7200VFDCentrifuge WARNING! WHILE OPENING AND CLOSING THE CENTRIFUGE COVER, PERSONNEL MUST ENSURE THAT ALL BODY LIMBS AND

Pagina 81

SAFETY 2-4 30 Sep 13 DE-7200VFDCentrifuge MSDS’S (CONT’D) MATERIAL DESCRIPTION - WHERE USED MSDS / Date Paints PPG Dimetcote 302H Green 302F0250 Re

Pagina 82

SECTION 3 - INSTALLATION 01 Jan 14 3-1 DE-7200VFDCentrifuge GENERAL This section describes the recommended installation procedure for the DE-72

Pagina 83

INSTALLATION 3-2 01 Jan 14 DE-7200VFDCentrifuge TOP COVER OPENING/CLOSING PROCEDURES The proper procedures for opening and closing the top cover of

Pagina 84

INSTALLATION 01 Jan 14 3-3 DE-7200VFDCentrifuge INSTALLATION SEQUENCE Following is the sequence of steps for installing the centrifuge. The sequen

Pagina 85

INSTALLATION 3-4 01 Jan 14 DE-7200VFDCentrifuge REQUIRED CLEARANCES AND POSITIONING (CONT’D) Figure 3-1. Required Opening Clearances for Cabinet Do

Pagina 86

INSTALLATION 01 Jan 14 3-5 DE-7200VFDCentrifuge While the centrifuge and control cabinet are still mounted on the shipping skids, they may b

Pagina 87

INSTALLATION 3-6 01 Jan 14 DE-7200VFDCentrifuge EQUIPMENT HANDLING (CONT’D) Figure 3-3. DE-7200 Control Cabinet Lifting Arrangement EQUIPMENT POSIT

Pagina 88

INSTALLATION 01 Jan 14 3-7 DE-7200VFDCentrifuge Figure 3-4. Centrifuge Installation Site Layout

Pagina 89

INSTALLATION 3-8 01 Jan 14 DE-7200VFDCentrifuge EQUIPMENT POSITIONING AND MOUNTING (CONT’D) Figure 3-5. Centrifuge Mounting LIQUID AND SOLID DISCHA

Pagina 90

INSTALLATION 01 Jan 14 3-9 DE-7200VFDCentrifuge Liquid Discharge The liquid discharge collector may be bolted directly to the centrifuge case; how

Pagina 91

UNIT NUMBER IS KEY TO DERRICK SERVICE All inquiries to Derrick must include the equipment unit number. The stainless steel unit number tag attached t

Pagina 92

INSTALLATION 3-10 01 Jan 14 DE-7200VFDCentrifuge LOWER AND SECURE ROTATING ASSEMBLY Note! Do not discard the rubber strips between bearing pillow b

Pagina 93

INSTALLATION 01 Jan 14 3-11 DE-7200VFDCentrifuge 3. Install two jack bolts in top half of each pillow block, and thread bolts through lower halve

Pagina 94

INSTALLATION 3-12 01 Jan 14 DE-7200VFDCentrifuge FEED AND FLUSH CONNECTIONS (CONT’D) Figure 3-9. Feed Assembly Figure 3-10. Feed Line Connections

Pagina 95

INSTALLATION 01 Jan 14 3-13 DE-7200VFDCentrifuge COMPRESSED AIR Explosion-proof control cabinets require a source of clean, preferably instrument

Pagina 96

INSTALLATION 3-14 01 Jan 14 DE-7200VFDCentrifuge Note that power may be connected with either a single heavy-gage cable or split between two smaller

Pagina 97

INSTALLATION 01 Jan 14 3-15 DE-7200VFDCentrifuge BOWL, CONVEYOR, AND FEED PUMP MOTOR CONNECTIONS The bowl and conveyor drive motors require three-

Pagina 98 - CONTROL COMPONENT INDICATORS

INSTALLATION 3-16 01 Jan 14 DE-7200VFDCentrifuge TANK LEVEL SWITCH CONNECTIONS (CONT’D) Figure 3-15. Typical Tank Level Switch Connections POLARITY

Pagina 99

INSTALLATION 01 Jan 14 3-17 DE-7200VFDCentrifuge WARNING! CENTRIFUGE MUST BE OPERATED AT THE DESIGNATED SUPPLY VOLTAGE. DANGER! DANGER! HIGH VOL

Pagina 100 - MAINTENANCE

INSTALLATION 3-18 01 Jan 14 DE-7200VFDCentrifuge MACHINE STARTUP Refer to Section 4 for initial startup and operating procedures for the centrifuge.

Pagina 101

SECTION 4 - OPERATING INSTRUCTIONS 30 Sep 13 4-1 DE-7200VFDCentrifuge GENERAL The procedures in this section are for use only by trained personn

Pagina 102

ABOUT THIS MANUAL In this electronic manual, all sections and paragraphs listed in the CONTENTS are linked to the corresponding text. Navigate

Pagina 103 - DE-7200VFDCentrifuge

OPERATING INSTRUCTIONS 4-2 30 Sep 13 DE-7200VFDCentrifuge TOP COVER OPENING/CLOSING PROCEDURES The proper procedures for opening and closing the top

Pagina 104

OPERATING INSTRUCTIONS 30 Sep 13 4-3 DE-7200VFDCentrifuge DANGER! USE EXTREME CAUTION WHEN OPERATING CENTRIFUGE WITH PURGE SYSTEM BYPASSED. DANGER

Pagina 105

OPERATING INSTRUCTIONS 4-4 30 Sep 13 DE-7200VFDCentrifuge INITIAL STARTUP (CONT’D) 6. Apply electric power to centrifuge. The following screen will

Pagina 106

OPERATING INSTRUCTIONS 30 Sep 13 4-5 DE-7200VFDCentrifuge b. Select Download to update VFD settings with new motor data. This will cause pump to a

Pagina 107

OPERATING INSTRUCTIONS 4-6 30 Sep 13 DE-7200VFDCentrifuge NORMAL STARTUP Note! If Centrifuge is Heated, Before Starting Centrifuge Follow COLD CLIM

Pagina 108

OPERATING INSTRUCTIONS 30 Sep 13 4-7 DE-7200VFDCentrifuge Note! Pump will not start until actual bowl speed is within 120RPM of setting. 11. Adjus

Pagina 109

OPERATING INSTRUCTIONS 4-8 30 Sep 13 DE-7200VFDCentrifuge OPERATION (CONT’D) Adjustment of one parameter may produce the desired clarity of liquid e

Pagina 110

OPERATING INSTRUCTIONS 30 Sep 13 4-9 DE-7200VFDCentrifuge as the torque remains below the set limit. If the slurry is low in viscosity and density,

Pagina 111

OPERATING INSTRUCTIONS 4-10 30 Sep 13 DE-7200VFDCentrifuge Pond Depth (Cont’d) Six adjustable weir plates are provided on the liquid bowl head to fa

Pagina 112

OPERATING INSTRUCTIONS 30 Sep 13 4-11 DE-7200VFDCentrifuge To adjust pond depth, proceed as follows: WARNING! DO NOT OPEN COVER OR ATTEMPT ANY ADJ

Pagina 113

CONTENTS 01 Jan 14 TOC-1 DE-7200VFDCentrifuge Section Page Date 1 - Introduction ...

Pagina 114

OPERATING INSTRUCTIONS 4-12 30 Sep 13 DE-7200VFDCentrifuge BEARING TEMPERATURES Bearing temperature trends may be viewed in graphical form on the Be

Pagina 115

OPERATING INSTRUCTIONS 30 Sep 13 4-13 DE-7200VFDCentrifuge SYSTEM DIAGNOSTICS Built-in system diagnostics continually analyze the control system fo

Pagina 116

OPERATING INSTRUCTIONS 4-14 30 Sep 13 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES If an alarm or fault occurs, a banner will appear at the bottom

Pagina 117

OPERATING INSTRUCTIONS 30 Sep 13 4-15 DE-7200VFDCentrifuge Figure 4-10. Alarm Screen Buttons VFD STATUS Status screens (Figure 4-11 through 4-13

Pagina 118

OPERATING INSTRUCTIONS 4-16 30 Sep 13 DE-7200VFDCentrifuge VFD STATUS (CONT’D) Figure 4-12. Conveyor VFD Screen Figure 4-13. Pump VFD Screen PUMP

Pagina 119

OPERATING INSTRUCTIONS 30 Sep 13 4-17 DE-7200VFDCentrifuge Figure 4-14. Pump VFD Fault Status Screen VFD TEMPERATURE TRENDS The historical tempera

Pagina 120

OPERATING INSTRUCTIONS 4-18 30 Sep 13 DE-7200VFDCentrifuge VFD FAULT RESET (CONT’D) Figure 4-16. Fault Reset Screen SETUP SCREEN The Setup screen (

Pagina 121

OPERATING INSTRUCTIONS 30 Sep 13 4-19 DE-7200VFDCentrifuge By entering “User1” for user name and password “1-1-1-1” on the Login screen, the opera

Pagina 122

OPERATING INSTRUCTIONS 4-20 30 Sep 13 DE-7200VFDCentrifuge CLEAN OUT (CONT’D) Figure 4-20. Clean Out Screen Provision is included for selecting the

Pagina 123

OPERATING INSTRUCTIONS 30 Sep 13 4-21 DE-7200VFDCentrifuge NORMAL SHUTDOWN The normal shutdown procedure is to be used for controlled stopping of o

Pagina 124

CONTENTS TOC-2 01 Jan 14 DE-7200VFDCentrifuge Section Page Date 4 - Operating Instructions ...

Pagina 125

OPERATING INSTRUCTIONS 4-22 30 Sep 13 DE-7200VFDCentrifuge Excessive Bowl Speed A sensor that detects the rotating speed of the bowl provides an inp

Pagina 126

OPERATING INSTRUCTIONS 30 Sep 13 4-23 DE-7200VFDCentrifuge EMERGENCY SHUTDOWN Two options are available to stop the centrifuge in an emergency:

Pagina 128

SECTION 5 - MAINTENANCE 31 Dec 13 5-1 DE-7200VFDCentrifuge GENERAL This section describes preventive and corrective maintenance procedures for th

Pagina 129

MAINTENANCE 5-2 31 Dec 13 DE-7200VFDCentrifuge PREVENTIVE MAINTENANCE Preventive maintenance consists of inspection, cleaning, and lubrication.

Pagina 130

MAINTENANCE 31 Dec 13 5-3 DE-7200VFDCentrifuge LUBRICATION CHART No. Location Amount Interval Type Application Notes 1 Main bearings 6 cm3 (

Pagina 131

MAINTENANCE 5-4 31 Dec 13 DE-7200VFDCentrifuge GEARBOX OIL LEVEL CHECK (CONT’D) 4. Rotate gearbox until the housing marks are at top dead center (

Pagina 132

MAINTENANCE 31 Dec 13 5-5 DE-7200VFDCentrifuge 9. Re-fill gearbox with correct product and quantity listed in Lubrication Chart. 10. Re-install fil

Pagina 133

MAINTENANCE 5-6 31 Dec 13 DE-7200VFDCentrifuge DRIVE BELT REPLACEMENT (CONT’D) Figure 5-2. Conveyor Drive Clutch Figure 5-3. Drive Belt Tensioni

Pagina 134

MAINTENANCE 31 Dec 13 5-7 DE-7200VFDCentrifuge PURGE SYSTEM Bypassing Purge System The purge unit may be bypassed when necessary to apply electric p

Pagina 135

CONTENTS 01 Jan 14 TOC-3 DE-7200VFDCentrifuge Section Page Date 5 - Maintenance (Cont’d) Troubleshooting ...

Pagina 136

MAINTENANCE 5-8 31 Dec 13 DE-7200VFDCentrifuge Visual Inspection and Checks (Cont’d) 3. Check condition of the purge unit air filter element, and

Pagina 137

MAINTENANCE 31 Dec 13 5-9 DE-7200VFDCentrifuge Leakage Compensation Test A Magnahelic gage and hose kit available from Derrick is required to monito

Pagina 138

MAINTENANCE 5-10 31 Dec 13 DE-7200VFDCentrifuge Minimum Pressure Sensor Setting The setting of the minimum pressure sensor should be checked as fol

Pagina 139

MAINTENANCE 31 Dec 13 5-11 DE-7200VFDCentrifuge Cleaning Purge Unit Filter Do not use solvents on any part of the filter assembly installed inside t

Pagina 140

MAINTENANCE 5-12 31 Dec 13 DE-7200VFDCentrifuge Rotating Assembly Removal (Cont’d) Figure 5-4. Conveyor Torque Limiter Clutch 6. Loosen nuts secu

Pagina 141 - 16472-00-002

MAINTENANCE 31 Dec 13 5-13 DE-7200VFDCentrifuge 10. Attach a hoist capable of lifting at least 4000 lbs (1800 kg) to rotating assembly. 11. Properly

Pagina 142

MAINTENANCE 5-14 31 Dec 13 DE-7200VFDCentrifuge Cleaning and Inspection (Cont’d) A (mm) Radial Wear (mm) 19.2 0 20.2 1 21.2 2 22.2 3 23.2 4 24.2

Pagina 143 - 16472-00-003

MAINTENANCE 31 Dec 13 5-15 DE-7200VFDCentrifuge HARDWARE TORQUE SPECIFICATIONS Use only hardware that is approved by Derrick Corporation. The use of

Pagina 144

MAINTENANCE 5-16 31 Dec 13 DE-7200VFDCentrifuge RECOMMENDED SPARE PARTS (CONT’D) Part No. Description Consumable 2-Yr Qty Base - 16601-00-001

Pagina 145 - 16472-00-004

MAINTENANCE 31 Dec 13 5-17 DE-7200VFDCentrifuge Part No. Description Consumable 2-Yr Qty Control Cabinet - 16472-00-002 G0007698 Fuse, 60A,

Pagina 147 - 16472-00-005

MAINTENANCE 5-18 31 Dec 13 DE-7200VFDCentrifuge TROUBLESHOOTING (CONT’D) In case of control system malfunction, with electric power shut down, lock

Pagina 148

MAINTENANCE 31 Dec 13 5-19 DE-7200VFDCentrifuge TROUBLESHOOTING DE-7200 VFD CENTRIFUGE Possible Cause Isolation Procedure & Corrective Action F

Pagina 149 - PURPOSE

MAINTENANCE 5-20 31 Dec 13 DE-7200VFDCentrifuge TROUBLESHOOTING DE-7200 VFD CENTRIFUGE Possible Cause Isolation Procedure & Corrective Action

Pagina 150 - DE-7200VFDCentrifuge

MAINTENANCE 31 Dec 13 5-21 DE-7200VFDCentrifuge TROUBLESHOOTING DE-7200 VFD CENTRIFUGE Possible Cause Isolation Procedure & Corrective Action F

Pagina 151

MAINTENANCE 5-22 31 Dec 13 DE-7200VFDCentrifuge TROUBLESHOOTING (CONT’D) Figure 5-10. Air Conditioner Electrical Schematic Diagram

Pagina 152

MAINTENANCE 31 Dec 13 5-23 DE-7200VFDCentrifuge Figure 5-11. Air Conditioner Electrical Schematic Diagram - 230Vac RTD Sensing

Pagina 153

MAINTENANCE 5-24 31 Dec 13 DE-7200VFDCentrifuge Figure 5-12. Air Conditioner Electrical Schematic Diagram - 24Vdc RTD Sensing

Pagina 154

MAINTENANCE 31 Dec 13 5-25 DE-7200VFDCentrifuge Figure 5-13. Air Conditioner Electrical Components Locations ALARM AND FAULT MESSAGES Intervention

Pagina 155

MAINTENANCE 5-26 31 Dec 13 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F1001 - Bowl High Torque Alarm, Reduce Feed Rate

Pagina 156 - Electric Power Connections

MAINTENANCE 31 Dec 13 5-27 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F1017 - Bowl VFD Drive OL Alarm, Ref Troubleshooti

Pagina 157 - Ethernet Connections

SECTION 1 - INTRODUCTION 20 Sep 12 1-1 DE-7200VFDCentrifuge OVERVIEW This manual provides instructions for installing and operating the DE-7200

Pagina 158 - Appendix A-HMIServerSystem

MAINTENANCE 5-28 31 Dec 13 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F2012 - Conveyor VFD Fault and Shutdown, Ref Trou

Pagina 159 - Operation

MAINTENANCE 31 Dec 13 5-29 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F3010 - Pump VFD Communications Error Communicatio

Pagina 160 - Operation (Cont’d)

MAINTENANCE 5-30 31 Dec 13 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F3021 - Pump Motor Thermal Overload Check Pump Mo

Pagina 161

MAINTENANCE 31 Dec 13 5-31 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F4003 - Liquid End Main Bearing High Temperature A

Pagina 162

MAINTENANCE 5-32 31 Dec 13 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F4006 - Solid End Main Bearing High Temperature F

Pagina 163

MAINTENANCE 31 Dec 13 5-33 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F7022 - Electrical Enclosure High Temperature Faul

Pagina 164 - REFERENCE DRAWINGS

MAINTENANCE 5-34 31 Dec 13 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F9012 - External Communication Loss, Switched to

Pagina 165

MAINTENANCE 31 Dec 13 5-35 DE-7200VFDCentrifuge ALARM AND FAULT MESSAGES Cause Corrective Action F9099 - Centrifuge Sensor I/O Cable Has Been Remov

Pagina 166

MAINTENANCE 5-36 31 Dec 13 DE-7200VFDCentrifuge FAULT CROSS REFERENCE No. Fault No. Fault No. Fault 2 Auxiliary Input 38 Phase U to Grnd 8

Pagina 167

MAINTENANCE 31 Dec 13 5-37 DE-7200VFDCentrifuge Figure 5-14. VFD Indicators