7. Next press the <PCB Alignment Button> located on the AOI Top Menu Bar.
8. You may now use the Reference IDs on the Layout Viewer Display of the Assembly Drawing to confirm
the location of each of the (3) three devices used to define the CXF to scanned PCB image scale and
alignment when asked in the following steps.
Note: The following steps are the same as those used If REF IDs were screened onto the PCB. Assuming
that you have already created a <New Board Setup> up to and through the steps of Defining Board Size
and Alignment Points in the previous section, “Creating an AOI Mode Inspection Routine”. Continue to
the next steps to complete this process using the Layout Viewer tool to guide you through identifying the
correct Device IDs.
9. CXF to PCB alignment prompts will appear directly after a new board has been started and the size and
PCB alignment marks have been defined. At this point the system will display a <Confirm/Adjust Device
Position> dialog box displaying the (1
st
, 2
nd
and 3
rd
) alignment device in turn by REF ID, starting with the
lower-left location.
Defining 1 of 3 XY to PCB Alignment Devices
10. Locate the 1
st
component by “Device ID:” shown in the Device Position dialog box.
11. Move the Green Box to the center of the device using the mouse (drag-&-drop).
12. Next, use the keyboard <Left-Ctrl Key> in combination with the <Arrow Keys>, (<Left-Ctrl Key>+<Arrow
Keys>) to adjust the height and width of the Green Box so as to match the height and width of both pads
for the selected device.
Best Practice: The Keyboard Arrow Keys can also be used to adjust the location of the Green Box. To
do this (do not hold down the Ctrl Key), use only the Arrow Keys to move the box up, down, left or right.