By default each new device trained is given an ideal score of 700. Components that pass test at the 700
setting are exceptional clear, well-labeled, devices with good contrast and excellent solder characteristics;
most devices do not fit this criterion and therefore must be adjusted or fine-tuned.
NOTE: Adjusting threshold settings should only be performed if you already have trained a few templates and
reviewed and corrected any poorly defined templates. Poorly created templates should always be deleted and
replaced with improved versions. See: How to Fix Bad Templates
1. Right-click on the device outline. This will open a Device Editor Menu. Select <Edit Device> to inspect
the “Part Parameter” and verify that the settings are correct.
a. Pass Scores: Proper pass score setting vary from device-to-device.
b. A typical range for Pass setting can be between 600 – 700; but since few assemblies meet this
criterion, it is likely that this setting will require adjustment.
2. Reduce the Pass Score setting within the range stated for that device. NOTE: Adjustments should be
made in small 25-50 point increments.
Device Editor Menu Basic Parameters Extended Parameters
3. Other setting in the Basic and Extended Parameters menus can be ignored at this time as many
settings may not apply to a specific device and others are for advanced uses and require additional
specialized training.