Operations | Reference Manual
FocalSpot, Inc. | www.FocalSpot.com
Page | 80
1. Run the AOI Mode Production Launcher to launch the File Selection/Calibration Screen.
2. Use the <Test Directory> to browse to the path where inspection files are stored. The default path is
C:\Program Files\AOI\User”.
3. Select a saved inspection routine from the <Product> Pick List.
AOI Mode Launcher — File Selection/Calibration Screen
4. Use the <Set up Information> for details and instructions specific the selected PCB aka “Product”.
Example: Stand-off height, board in drawer position in reference to the table grid (e.g., O,12), or other
useful information specific to this PCB inspection setup. See, Create / Edit Board Notes for more
information on this topic.
5. Load a PCB and stage it at the stand-off height and table grid XY location described in the “Set Up
Information” Notes.
6. Press the <Test Board> Button. The AOI Mode Display Screen will now open along with all of the
setting saved for that specific inspection routine.
7. Press <Scanner/Scanner Setup> to launch the Epson Scanner software to capture an image of the
PCB. See,