11. Once a test is initiated, the system will prompt the user to stage a PCB into inspection area using the
appropriate stand-off height. Press the <Scanner Setup> button and follow the scanner setup
instructions for creating a new program.
Load Untested PCB for Inspection
12. If Automatic Alignment fails, first verify that the board is loaded correctly. If you are certain that the
board is loaded correctly and positioned in the proper location on the table grid; you can manually –re-
identify the first alignment point by double-clicking to the alignment location, then press the <Override>
button.
Board Aligned to Selected Point Alignment Error
13. Once the automatic alignment is satisfied; the Inspection will automatically begin and upon completion
report the results by displaying a Pass or Fail PCB Inspection Result dialog box. NOTE: If this results
in an Alignment error, the following error message will appear. Move the stage to the correct position
and magnification and press retry if this fails, press override.
14. The inspection will now continue unattended until finished.